Overview
The
ALU glazed sectional door, in manually operated and electrically operated
versions. These doors are used in private sector and in industrial and
commercial buildings. There is a choice of various specifications, finishes,
operating methods and track arrangements.
Specification/construction
The
ALU sectional overhead door, is an assembly of aluminium framed glazed
sections. Stucco embossed aluminium framed glazed sections. Stucco embossed
aluminium panels can also be fitted in the bottom section of the door
or alternatively an insulated panel. When the door is opened the sections
slide away under the ceiling. The door weight is balanced by means of
helical springs, so that manual operation is possible. In addition to
standard lift also high lift vertical lift , sloping roof track arrangements
and low headroom track arrangements are available.
Materials
- single
or double glazed sections made of anodised aluminium framing. Other
infill materials are also available : safety glass 4 mm polycarbonate
double glazing 16 mm, perforated sheet, steel mesh etc.
- thickness
of the panel is 45 mm
- height
of the panel according to the door size : 500 or 625 mm
- rubber
top, floor and side draught seals
- sendzimir
galvanised steel tracks
- hot
galvanised door fittings
- shoot
bolt for manually operated doors
- torsion
springs (alu. Finish) for about 25,000 cycles (higher on request)
Finish
- galvanised
spring shaft
- sections
anodised as standard
Dimensions
-
| maximum
door width * |
|
6500
mm |
| maximum
door height * |
|
7900
mm |
| maximum
door area * |
|
about
45 m2 |
| maximum
door width |
|
1000
mm |
* larger doors on request.
Drive
/ Operation
- standard
manually operated by pull cord
- manual
chain hoist (direct drive) 1:4 (max 25m )
- electrically
operated, direct drive or chain transmission, with push buttons (up-stop-down)
in press and hold mode' or press and release with timer return mode'
, including self-testing bottom safety edge (opto-sensor)
- various
actuators available ( see control systems
)
Safety
- finger
pinch protection
- steel
cables having a strength factor 6
- the
door is manufactured to meet requirements of ZH1/494
- spring
break safety (option)
- cable
break safety (option)
- slack
cable safety (option)
Mounting
structure requirements and connection
- with
electrically operated doors a main switch (or CEE plug) must be present
within a radius of 500 mm from the drive unit.
- separate
sheets with data concerning dimensions and structural provisions are
available for all models and tracks.
- send
us an enquiry for more information
Technical
specifications electric
operation
| mains
voltage |
|
230
V/50 Hz or 400V/50Hz/6A |
| degree
of protection |
|
IP54 |
Accessories
/ options
General
- PVC
hand grip
- fascia
panel
- spacer
profile
- ventilation
grilles
- outward
opening pass door, with night latch and door closer (max. Door width
5500 mm)
- hinges
in stainless steel
- matching
side door in separate framing
- finish
in RAL colour, customer specified
For
manually operated doors additionally
- spring
break safety
- cable
break safety
For
electrically operated doors additionally
- self-testing
safety edge (opto sensor)
- safety
photocell
- slack
cable safety
- control
panel for various kinds of 'timer' operation and/or traffic lights
- motor
unit, drive control and actuators in IP65
- 100%
rated drive for intensively used doors
- spring
loaded shoot bolt with isolator switch
- remote
control.
|


DOUBLE
GLAZING OPTION

|